ga('set', 'userId', {{USER_ID}}); // Set the user ID using signed-in user_id. Mitutoyo SJ-310
Mitutoyo

Surftest Series 310

    SJ-311/SJ-312

mitutoyo SJ-310

 

Large 5.7” color LCD with touch screen improves    operability and achieves high visibility.

Conforms to the roughness standards JIS-B0601-2001 JIS-B0601-1994, JIS-B0601-1982, VDA, ISO-1997 and ANSI.

Statistic measurements up to 3 parameters of 300 samples can be performed showing average, standard deviation, max, min, pass rate and histogram.

Up to ten measurement conditions along with stored data can be displayed and printed out by the built-in thermal printer.  It can also store up to 10 measurement conditions with the built-in memory.

 

The SJ-310 supports a micro-SD card (optional) for storage of up to 10,000 measurement values, 500 measuring conditions, 1000 measuring data, 500 image (BMP) data, 500 statistic data or auto save up to the last 10 sets of measurement data.

The total measurement and sectional measurement results can be displayed as well as the evaluation curve, BAC/ADC curve.

USB, Digimatic SPC output, RS-232C and External Software connectivity is supported.

Security is managed via a password lock to restrict function changes and unnecessary settings that could cause operation errors.

16 languages can be selected and are switchable.

It corresponds to cissoidal calculation in which one measurement can evaluate two different conditions.

 

User friendly, high-functionality display  unit

with integrated high-speed printer

 

The large 5.7-inch color graphic touch-screen LCD  provides excellent readability.  Furthermore, selecting icons from the touch panel display*1 provides intuitive and easy operation. The integrated high-speed printer also allows the user to perform the entire process from making measurements to printing the results with the push of a single button (START button).    *1 Text display can also be selected.

 

 

 

Standard drive unit

 Popular standard drive unit

 

Retractable drive unit

The detector is in the retracted

position at rest so it is immune from damage when inserted into a feature whose shape cannot be easily seen, such as a blind hole, etc

 

Transverse tracing drive u

Best suited for measurement

of narrow, shrouded workpiece features such as crankshaft bearings, EDM parts, etc.

(Patent Registered in Japan)

 

Specifications
Type of detector Standard drive unit type Retractable drive unit type Transverse tracing drive unit
Model No. SJ-310
(0.75mN type)
SJ-310
(4mN type)
SJ-310
(0.75mN type)
SJ-310
(4mN type)
SJ-310
(0.75mN type)
SJ-310
(4mN type)
Order No.                           inch/mm 178-571-01A 178-571-02A 178-573-01A 178-573-02A 178-575-01A 178-575-02A
Measuring range X axis .7"(17.5 mm) .22"(5.6 mm)
Detector Range 14400 µinch (-7900 µinch to +6300 µinch) [360 µm (-200 µm ~ +160 µm)]
Range/ resolution 14400 µinch / .8 µinch (360 µm / 0.02 µm)
4000 µinch / .2 µinch (100 µm / 0.006 µm)
1000 µinch / .08 µinch (25 µm / 0.002 µm)
Measuring speed In the measurement: .01inch/s (0.25mm/s), .02inch/s (0.5mm/s), .03inch/s (0.75mm/s), In the return: .04inch/s (1mm/s)
Measuring force / Stylus tip 0.75mN type: 0.75mN / 2µmR 60°,  4mN type: 4mN / 5µmR 90°
Skid force 400mN or less
Standard JIS’82 / JIS’94 / JIS’01 / ISO’97 / ANSI / VDA / FREE
Measured profiles Primary(P), Roughness(R), DF, R-Motif, W-Motif
Parameters Ra, Rc, Ry, Rz, Rq, Rt, Rmax*1, Rp, Rv, R3z, Rsk, Rku, Rc, RPc, Rsm, Rz1max*2, S, HSC, RzJIS*3, Rppi, RDa, RDq, Rlr, Rmr,
Rmr
(c), Rδc, Rk, Rpk, Rvk, Mr1, Mr2, A1, A2, Vo, la, lq, L0, Rpm, tp*4, Htp*4, R, Rx, AR, W, AW, Wx, Wte, Possible Customize
Graph analysis BAC and ADC curves
Filter Gaussian, 2CR75, PC75
Cut-off length lc .003, .01, .03, .1, .3" (0.08 , 0.25 , 0.8 , 2.5, 8 mm)
ls *5 100, 320 µinch (2.5 , 8 µm)
Sampling length .003, .01, .03, .1, .3" (0.08, 0.25 , 0.8 , 2.5, 8 mm)
Number of sampling lengths ×1, ×2, ×3, ×4, ×5, ×6, ×7, ×8, ×9, ×10, Arbitrary
.0118 ~ .6299"(.0001" Interval) [(0.3 ~ 16.0mm: 0.01mm  Interval)]
×1, ×2, ×3, ×4, ×5, ×6, ×7, ×8, ×9, ×10,
Arbitrary  .0118 ~ .22"(.0001" Interval) [(0.3 ~ 5.6mm: 0.01mm Interval)]
LCD dimensions 4.64" x 3.47" (117.8 × 88.2 mm)
Display languages Japanese, English, German, French, Italian, Spanish, Portuguese, Korean,
Traditional Chinese, Simplified Chinese, Czech, Polish, Hungarian Turkish, Swedish, Dutch
Measurement result display 1-parameter display: one parameter measurement result 4-parameter display: four parameter measurement results
Profile display: one parameter measurement result and the measured profile Trace display: The ten latest measurement results using the same parameter
Printing function Measurement conditions / Calculation results /  GO / NG judgement result / Calculation results for each sampling length / Measurement curve / BAC / ADC / Environmental setting information
External I/O USB I/F, Digimatic output, RS-232C I/F, External SW I/F
Functions Customization Desired parameters can be selected for calculation and display
GO/ NG judgement *6 Max rule / 16% rule / Average rule / Standard deviation (1s, 2s, 3s)
Storage of measurement condition Save the condition at power OFF
Storage Internal memory: Measurement condition (10 sets)
Memory card (option): 500 measurement conditions, 1000 measuring data, 10000 text data, 500 statistic data, 500 image data, 1 backup of machine setting, the last ten traces (Trace 10)
Calibration Saves last inputted nominal value of specimen / Average calibration with multiple measurement (MAX.12 times) is available
Power-saving Auto-sleep function (30-600sec) *7
Power supply Two-way power supply: battery (rechargeable Ni-MH battery) and AC adapter
*Charging time: about 4 hours (may vary due to ambient temperature)
*Endurance: about 1500 measurements (differs slightly due to use conditions / environment)
Size (W×D×H) Display unit 10.8"x 4.3" x 7.8"(275 × 109 × 198 mm)
Drive unit 4.5"x 0.9" x 8.9"(115 × 23 × 26.7 mm)
Mass About 1.8kg (Display unit + Drive unit + Standard detector)
Standard accessories 12AAM475   Connecting cable *8 12AAA217   Nosepiece for plane surface 12AAA218   Nosepiece for cylinder 12AAA216   Supporting leg
12BAK700   Calibration stage 12BAG834   Stylus pen 12BAL402   Protection sheet
270732   Printer paper (5 pieces)
12BAL400   Carrying case
Roughness reference specimen (Ra 3µm), AC  adapter, Philips screwdriver, Strap for stylus pen, Operation manual, Quick reference manual, Warranty
12AAM475   Connecting cable *8 12AAE643   Point-contact adapter 12AAE644   V-type adapter 12BAK700   Calibration stage 12BAG834   Stylus pen 12BAL402   Protection sheet
270732   Printer paper (5 pieces)
12BAL400   Carrying case
Roughness reference specimen (Ra 1µm), AC adapter, Philips screwdriver, Strap for stylus pen, Operation manual, Quick reference manual, Warranty
*1: Only for VDA/ANSI/JIS’82 standards.
*2: Only for JIS’97 standard.
*3: Only for JIS’01 standard.
*4: Only for ANSI standard.
*5: ls may not be switchable depending on a standard selected.
*6: Standard deviation only can be selected in ANSI.16% rule cannot be selected in VDA.
*7: Auto-sleep function is invalid when AC adapter is used.
*8: For connecting the calculation display unit and drive unit.
standard drive
retractable drive
traverse drive

Transverse Drive

Used with optional

V type adapter

And a support foot

 

measuring crankshaft

Standard Drive

Used with the optional cylindrical nosepiece

 

measuring cyllinder

Standard Drive

Used with the optional

 Support feet set

and a groove stylus

 

height adjusters for drive

 

Used with your height gage

And the Height gage adaptor

 

drive mounted to height stand

You can enter assessment conditions using ISO/JIS surface texture symbols.

(Patent registered in Japan, U.S.A., Germany, UK, France)(Patent pending in China)

 

evaluation screen

By specifying a tolerance in advance, you can display pass/fail results in color

 

OK

+ NG

- NG

Positive stylus contact indication

Stylus contact with the workpiece is indicated by color coding in the display. This is helpful when visibility of the surface to be measured is restricted (e.g. when measuring within a shrouded feature or groove).

No contact

no stylus contact
stylus in contact with material

contact

stylus in contact

724-368-8006  *  Fax 724-368-8005

 

Mitutoyo
mitutoyo SJ-310
standard drive
retractable drive
traverse drive
measuring crankshaft
measuring cyllinder
height adjusters for drive
drive mounted to height stand
evaluation screen
no stylus contact
stylus in contact with material
stylus in contact

Mitutoyo
mitutoyo SJ-310
measuring crankshaft
measuring cyllinder
height adjusters for drive
drive mounted to height stand
evaluation screen
no stylus contact
stylus in contact with material
stylus in contact