ga('set', 'userId', {{USER_ID}}); // Set the user ID using signed-in user_id. Mitutoyo SJ-410. Sj-411, Sj-412
724 368-8006
Rapp Industrial Sales Surface Finish Equipment
Mahr Pocket Surf IVMahr M1 - M2Mahr Pocket Surf PS1Mahr M300Mahr M300CMitutoyo SJ-410Mitutoyo SJ-210Mitutoyo SJ-310SRG-4000SRG-2000SPIStarrett SR100Starrett SR200Starrett SR300/400Reference StandardsFlexbar MetrologyTesa Rugo surf 10GTesa Rugo surf 20Tesa Rugo surf 90GCalibrationRepairAbout usSRG-4500Mahr S2Fowler XProStarrett SR160 Products
The new SJ-411/412 has numerous innovative features combined with high accuracy and a competitive price makes this instrument the new leader in its class.
One of the most econimacal skidded or skidless,easy to use roughness testers.
Unit has the ability to take straightness and waviness measurements using the skidless measurement function.
A skidless detector and a curved surface compensation function provide efficient evaulation of cylinder surface roughness
Parameters Ra, Rq, Rz, Ry, Rp, Rv, Rt, R3z, Rsk, Rku, Rc, RPc, RSm, Rmax, Rz1max, S, HSC, RzJIS, Rppi, Rq, RIr, Rmr, Rmr(c), RoX, Rk, Rpk, Rvk, Mr1, Mr2, A1, Vo, Aa, Aq, Lo, Rpm, tp, Htp, R, Rx, AR, W, AW, Wx, Wte, Possible customization.
Auto-calibration function that records the last time calibrated.
Password protection for setups is available for preventing accidental changes to settings
800µm/0.01µm
80µm/0.001µm
8µm/0.0001µm
High straightness drive unit Straightness/ traverse length
Speciications | |||||
Model No. | SJ-411 | SJ-412 | |||
inch/mm | 178-581-01A | 178-581-02A | 178-583-01A | 178-583-02A | |
Measuring range | X axis | 25mm (1inch) | 50mm (2inch) | ||
Z1 axis (detector unit) | 800µm, 80µm, 8µm *Up to 2,400µm with an optional stylus |
||||
Detector | Measuring principle | Differential inductance | |||
Resolution | 0.01µm (800µm range) / 0.001µm (80µm range) / 0.0001µm (8µm range) 0.4µinch (32000µinch) / 0.04µinch (3200µinch) / 0.004µinch (320µinch) | ||||
Stylus tip | 60°/ 2µm (80µinch) | 90°/ 5µm (200µinch) | 60°/ 2µm (80µinch) | 90°/ 5µm (200µinch) | |
Measuring force | 0.75mN | 4mN | 0.75mN | 4mN | |
Radius of skid curvature | R40 mm (R1.57") | ||||
Measuring method | Skidded measurement / skidless measurement | ||||
Drive unit: X-axis | Measuring speed | 0.05 , 0.1 , 0.2 , 0.5 , 1.0mm/s (0.002, 0.004, 0.02, 0.04 inch/s) | |||
Drive speed | 0.5 , 1, 2, 5mm/s (0.02, 0.04, 0.08, 0.2 inch/s) | ||||
Straightness | 0.3µm / 25mm (12µinch/ 1inch) | 0.5µm / 50mm (20µinch/ 2inch) | |||
Height-tilt adjustment unit | Height adjustment | 10mm (0.39inch) | |||
Tilt adjustment | ±1.5° | ||||
Standards | JIS1982 / JIS1994 / JIS2001 / ISO1997 / ANSI / VDA | ||||
Parameters | Ra, Rq, Rz, Ry, Rp, Rv, Rt, R3z, Rsk, Rku, Rc, RPc, RSm, Rmax*1, Rz1max*2, S, HSC, RzJIS*3, Rppi, RΔa, RΔq, Rlr, Rmr, Rmr(c), Rsc, Rk, Rpk, Rvk, Mr1, Mr2, A1, A2, Vo, la, lq, Lo, Rpm, tp*4, Htp*4, R, Rx, AR, W, AW, Wx, Wte, Possible Customize | ||||
Measured profiles | Primary, Roughness, DF, Filtered waviness curve, R-Motif, W-Motif | ||||
Graph analysis | BAC and ADC curves | ||||
Data compensation | Parabola/ Hyperbola/ Ellipse/ Circle/ Conic/ Tilting, Compensation off | ||||
Filter | 2CR, PC75, Gaussian filter | ||||
Cut-off length | lc | 0.08 , 0.25 , 0.8 , 2.5 , 8.0mm | |||
ls *5 | 2.5, 8.0, 25mm (100, 320, 1000µinch) | ||||
Sample length | 0.08 , 0.25 , 0.8 , 2.5 , 8.0 , 25.0mm | ||||
Number of sampling lengths | ×1, ×2, ×3, ×4, ×5, ×6, ×7, ×8, ×9, ×10, ×11, ×12, ×13, ×14, ×15, ×16, ×17, ×18, ×19, ×20 | ||||
Arbitrary length | 0.1~25mm | 0.1~50mm | |||
Functions | Customization | Desired parameters can be selected for calculation and display | |||
Simple contour analysis function | Step, Step volume, Dimensions, Coordinate difference | ||||
DAT function | Helps to adjust leveling during skidless measurement | ||||
Real sampling function | Samples stylus displacement for a specified time without engaging detector traverse. | ||||
Statistical processing | Static measurement (max. 3 parameters) is possible. Static processing for MAX, MIN, AVERAGE, standard deviation, histogram and pass rate is possible | ||||
GO/ NG judgement*6 | Max rule / 16% rule / Average rule / Standard deviation (1s, 2s, 3s) | ||||
Storage functions | 10 measuring conditions can be stored in internal memory | ||||
Printing function | Measurement conditions / Calculation results / GO / NG judgement result / Calculation results for each sampling length / Measurement curve / BAC / ADC / Environmental setting information | ||||
Display languages | Japanese, English, German, French, Italian, Spanish, Portuguese, Korean, Traditional Chinese, Simplified Chinese, Czech, Polish, Hungarian Turkish, Swedish, Dutch | ||||
Storage | Internal memory: Measurement condition (10 sets) Memory card (option): 500 measurement condition, 10000 measuring data, 10000 text data, 500 statistic data, 1 backup of machine setting, the last ten traces (Trace 10) |
||||
External I/O | USB I/F, Digimatic output, RS-232C I/F, External SW I/F | ||||
Power supply | Battery | Two-way power supply: battery (rechargeable Ni-MH battery)
and AC adapter *Charging time: about 4 hours (may vary due to ambient temperature) *Endurance: about 1500 measurements (differs slightly due to use conditions / environment) |
|||
Power consumption | 50W | ||||
Size (W×D×H) | Display unit | 275×198×109mm (10.83×4.29×7.80inch) | |||
Height adjustment unit | 130.9×63×99mm (5.16×2.48×3.90 inch) | ||||
Drive unit | 128×35.8×46.6mm (5.04×1.41×1.83 inch) | 154.5×35.8×46.6mm (6.08×1.41×1.83inch) | |||
Display unit | 1.7kg | ||||
*1M:aOssnly for VDA/ANSI/JIHS'e8i2ghsttaanddjuasrtdms.ent
unit *2: Only for JIS'97 standaDrrdiv.e unit |
0.4kg | ||||
0.6kg | 0.64kg | ||||
*3: Only for JIS'01
standard. *4: Only for ANSI standard. *5St:alnsdmaradyancocetsbseorsiewsitchable depending on standard selecte *6: Standard deviation only can be selected in ANSI.16% rul |
Detector*7, Stylus*8, Roughness specimen 270732
AC adapter, Philips screwdriver, d. Printing paper 12BAG834 Touch pen Strap for stylus pen, Operation manual, Quick e cann1o2t BbAe Lse4l0e2ctedToinucVhD-sAcr.een protection sheet 12AAN041 Carrying case reference manual, Warranty |
||||
*7: Either No.178-396-2 or No.178-397-2 is supplied as a standard accessory depending on the Order No. of the main unit for SJ-410 Series. | |||||
*8: The standard stylus (No.12AAC731 or No.12AAB403), which is compatible with the detector supplied, is a standard accessory. |
Blueprint design code which can be easily keyed from this screen to set the evaluation
Waviness Parameters
Very usefull screen for the recommended cut-off values
One measurement can evaluate two different conditions.
724-368-8006 * Fax 724-368-8005